Bearing Finder
Customizable search tool featuring exhaustive data sets, comprehensive part
interchanges and interactive CAD drawings
CAD (0)
▾
Clear
Filter
d (in)
At Least :
No More Than :
Available Range: 0.75 to 3.5433
Available Range: 0.75 to 3.5433
d (mm)
At Least :
No More Than :
Available Range: 19.05 to 90
Available Range: 19.05 to 90
L (in)
At Least :
No More Than :
Available Range: 4.375 to 10.875
Available Range: 4.375 to 10.875
L (mm)
At Least :
No More Than :
Available Range: 111 to 276
Available Range: 111 to 276
J (in)
At Least :
No More Than :
Available Range: 3.5469 to 9.375
Available Range: 3.5469 to 9.375
J (mm)
At Least :
No More Than :
Available Range: 90 to 238
Available Range: 90 to 238
A (in)
At Least :
No More Than :
Available Range: 1.0625 to 3.7031
Available Range: 1.0625 to 3.7031
A (mm)
At Least :
No More Than :
Available Range: 27 to 94
Available Range: 27 to 94
A1 (in)
At Least :
No More Than :
Available Range: 0.8125 to 2.5937
Available Range: 0.8125 to 2.5937
A1 (mm)
At Least :
No More Than :
Available Range: 21 to 66
Available Range: 21 to 66
Item # |
d |
L |
J |
A |
A1 |
---|---|---|---|---|---|
UKFCX09D1 (when used with HA2309) | d N/A 1.4375 in36.513 mm | L N/A 6.0937 in155.0 mm | J N/A 5.1250 in130.0 mm | A N/A 1.4531 in37.0 mm | A1 N/A 0.9687 in25.000 mm |
UKFCX09D1 (when used with HE2309X) | d N/A 1.5000 in38.100 mm | L N/A 6.0937 in155.0 mm | J N/A 5.1250 in130.0 mm | A N/A 1.4531 in37.0 mm | A1 N/A 0.9687 in25.000 mm |
UKFCX09D1 (when used with HS2309X) | d N/A 1.6250 in41.275 mm | L N/A 6.0937 in155.0 mm | J N/A 5.1250 in130.0 mm | A N/A 1.4531 in37.0 mm | A1 N/A 0.9687 in25.000 mm |
UKFCX10D1 (when used with H2310X) | d N/A 1.7717 in45.000 mm | L N/A 6.3750 in162.0 mm | J N/A 5.3594 in136.0 mm | A N/A 1.6094 in41.0 mm | A1 N/A 0.9687 in25.000 mm |
UKFCX10D1 (when used with HA2310) | d N/A 1.6875 in42.863 mm | L N/A 6.3750 in162.0 mm | J N/A 5.3594 in136.0 mm | A N/A 1.6094 in41.0 mm | A1 N/A 0.9687 in25.000 mm |
UKFCX10D1 (when used with HE2310X) | d N/A 1.7500 in44.450 mm | L N/A 6.3750 in162.0 mm | J N/A 5.3594 in136.0 mm | A N/A 1.6094 in41.0 mm | A1 N/A 0.9687 in25.000 mm |
UKFCX10D1 (when used with HS2310X) | d N/A 1.6250 in41.275 mm | L N/A 6.3750 in162.0 mm | J N/A 5.3594 in136.0 mm | A N/A 1.6094 in41.0 mm | A1 N/A 0.9687 in25.000 mm |
UKFCX11D1 (when used with H2311X) | d N/A 1.9685 in50.000 mm | L N/A 7.0937 in180.0 mm | J N/A 5.9844 in152.0 mm | A N/A 1.8906 in48.0 mm | A1 N/A 0.9687 in26 mm |
UKFCX11D1 (when used with HA2311) | d N/A 1.9375 in49.213 mm | L N/A 7.0937 in180.0 mm | J N/A 5.9844 in152.0 mm | A N/A 1.8906 in48.0 mm | A1 N/A 0.9687 in26 mm |
UKFCX11D1 (when used with HE2311X) | d N/A 2.0000 in50.800 mm | L N/A 7.0937 in180.0 mm | J N/A 5.9844 in152.0 mm | A N/A 1.8906 in48.0 mm | A1 N/A 0.9687 in26 mm |
UKFCX11D1 (when used with HS2311XY) | d N/A 1.8750 in47.625 mm | L N/A 7.0937 in180.0 mm | J N/A 5.9844 in152.0 mm | A N/A 1.8906 in48.0 mm | A1 N/A 0.9687 in26 mm |
UKFCX12D1 (when used with H2312X) | d N/A 2.1654 in55.000 mm | L N/A 7.6250 in194.0 mm | J N/A 6.5000 in165.0 mm | A N/A 2.0781 in53.0 mm | A1 N/A 1.3125 in33.000 mm |
UKFCX12D1 (when used with HS2312) | d N/A 2.1250 in53.975 mm | L N/A 7.6250 in194.0 mm | J N/A 6.5000 in165.0 mm | A N/A 2.0781 in53.0 mm | A1 N/A 1.3125 in33.000 mm |
UKFCX13D1 (when used with H2313X) | d N/A 2.3622 in60.000 mm | L N/A 7.6250 in194.0 mm | J N/A 6.5000 in165.0 mm | A N/A 2.0781 in53.0 mm | A1 N/A 1.3125 in33.000 mm |
UKFCX13D1 (when used with HA2313) | d N/A 2.1875 in55.563 mm | L N/A 7.6250 in194.0 mm | J N/A 6.5000 in165.0 mm | A N/A 2.0781 in53.0 mm | A1 N/A 1.3125 in33.000 mm |
UKFCX13D1 (when used with HE2313X) | d N/A 2.2500 in57.150 mm | L N/A 7.6250 in194.0 mm | J N/A 6.5000 in165.0 mm | A N/A 2.0781 in53.0 mm | A1 N/A 1.3125 in33.000 mm |
UKFCX13D1 (when used with HS2313X) | d N/A 2.3750 in60.325 mm | L N/A 7.6250 in194.0 mm | J N/A 6.5000 in165.0 mm | A N/A 2.0781 in53.0 mm | A1 N/A 1.3125 in33.000 mm |
UKFCX15D1 (when used with H2315X) | d N/A 2.5591 in65.000 mm | L N/A 8.7500 in222.0 mm | J N/A 7.4844 in190.0 mm | A N/A 2.2500 in57.0 mm | A1 N/A 1.3750 in35.000 mm |
UKFCX15D1 (when used with HA2315) | d N/A 2.4375 in61.913 mm | L N/A 8.7500 in222.0 mm | J N/A 7.4844 in190.0 mm | A N/A 2.2500 in57.0 mm | A1 N/A 1.3750 in35.000 mm |
UKFCX15D1 (when used with HE2315X) | d N/A 2.5000 in63.500 mm | L N/A 8.7500 in222.0 mm | J N/A 7.4844 in190.0 mm | A N/A 2.2500 in57.0 mm | A1 N/A 1.3750 in35.000 mm |
UKFCX16D1 (when used with H2316X) | d N/A 2.7559 in70.000 mm | L N/A 10.2500 in260.0 mm | J N/A 8.6250 in219.0 mm | A N/A 2.4062 in61.0 mm | A1 N/A 1.4062 in36.000 mm |
UKFCX16D1 (when used with HA2316) | d N/A 2.6875 in68.263 mm | L N/A 10.2500 in260.0 mm | J N/A 8.6250 in219.0 mm | A N/A 2.4062 in61.0 mm | A1 N/A 1.4062 in36.000 mm |
UKFCX16D1 (when used with HE2316X) | d N/A 2.7500 in69.850 mm | L N/A 10.2500 in260.0 mm | J N/A 8.6250 in219.0 mm | A N/A 2.4062 in61.0 mm | A1 N/A 1.4062 in36.000 mm |
UKFCX17D1 (when used with H2317X) | d N/A 2.9528 in75.000 mm | L N/A 10.2500 in260.0 mm | J N/A 8.6250 in219.0 mm | A N/A 2.4062 in61.0 mm | A1 N/A 1.4062 in36.000 mm |
UKFCX17D1 (when used with HA2317X) | d N/A 2.9375 in74.613 mm | L N/A 10.2500 in260.0 mm | J N/A 8.6250 in219.0 mm | A N/A 2.4062 in61.0 mm | A1 N/A 1.4062 in36.000 mm |